{"product_id":"penlon-prima-460-anesthesia-machine","title":"Penlon Prima 460 Anesthesia Machine","description":"\u003ch2 style=\"font-size:24px;line-height:1.3;margin:28px 0 12px;\"\u003eDetails\u003c\/h2\u003e\u003cp\u003eThe Penlon Prima 460 combines touchscreen controls, ventilation functions and an integrated anesthesia workstation layout.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSelectable waveform and respiratory-loop views accompany airway-pressure information.\u003c\/li\u003e\n\u003cli\u003eMechanical anti-hypoxic protection and backup oxygen delivery are provided.\u003c\/li\u003e\n\u003cli\u003eSelectatec back bar accepts compatible vaporizers.\u003c\/li\u003e\n\u003cli\u003eThree cylinder-yoke positions accommodate oxygen, nitrous oxide and medical air.\u003c\/li\u003e\n\u003cli\u003eIntegrated gas scavenging, dual flow sensors, and audible and visual alarms.\u003c\/li\u003e\n\u003cli\u003eTop shelf supports patient-monitor mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eConfirm the supplied configuration and accessories before ordering. Photos may show optional equipment.\u003c\/p\u003e\u003ch2 style=\"font-size:24px;line-height:1.3;margin:28px 0 12px;\"\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;table-layout:auto;border-collapse:collapse;margin:0 0 16px;font-size:16px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"text-align:left;padding:12px;background:#f3f6f8;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align:left;padding:12px;background:#f3f6f8;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003ePenlon Prima 460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003e00105PRS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003e15.4-inch high-definition touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eDisplay views\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eAirway pressure plus two selectable waveform or loop views\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eWaveform selections\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eFlow rate and tidal volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eRespiratory-loop selections\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003ePressure–volume (P–V), volume–flow (V–F) and pressure–flow (P–F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eVentilation modes\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eVCV, PCV, PSV, SPONT, SIMV, SMMV and Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003ePEEP\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eSupported in all listed modes except Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eFlow measurement\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eDual flow sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eAlarm output\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eAudible and visual indications\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eVaporizer mounting\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eSelectatec back bar for compatible vaporizers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eCylinder connections\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eThree available yokes for O2, N2O and medical air; confirm supplied configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eOxygen safeguards\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eMechanical anti-hypoxic device, total-flow display and backup oxygen delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eScavenging\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eAnesthetic-gas scavenging system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eBackup battery\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eUp to one hour; operating conditions affect runtime.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:34%;text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;font-weight:600;\"\u003eMonitor support\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:12px;border:1px solid #dce2e6;\"\u003eTop shelf with patient-monitor mounting system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eConfirm the supplied gas connections, vaporizers and accessories with Restful Relaxation before ordering. Equipment dimensions, weight and electrical requirements are available on request.\u003c\/p\u003e\u003ch2 style=\"font-size:24px;line-height:1.3;margin:28px 0 12px;\"\u003eDocuments \u0026amp; Resources\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/drevet\/documents\/Penlon%20Prima%20460%20Sales%20Sheets_02.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePenlon Prima 460 Sales Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eProduct literature may show alternative configurations and optional accessories. Refer to your order confirmation for included equipment.\u003c\/p\u003e","brand":"Restful Relaxation","offers":[{"title":"Default Title","offer_id":67650038989097,"sku":"00105PRS","price":23590.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/9984\/4393\/files\/upload-1792269830761.png?v=1792269832","url":"https:\/\/restfulrelaxation.com\/products\/penlon-prima-460-anesthesia-machine","provider":"Restful Relaxation","version":"1.0","type":"link"}